FUHRER WIRE AND CABLE

PRODUCTS

ผลิตภัณฑ์แยกตามแรงดันไฟฟ้า

Medium Voltage Cables

POWER CABLES WITH XLPE INSULATED FOR RATED VOLTAGE OF 12/20(24)

CONDUCTOR :Compact round stranded annealed copper

INSULATION :Cross-linked polyethylene ( XLPE )

OUTER SHEATH :Black polyethylene ( Optional : Polyvinyl chloride (S 12)

CLASSIFICATION :Maximum Conductor T'emperature 90 C. (Normal operation) Maximum Conductor T'emperature 250 C (Short - circuit at 5 s maximum duration)

REFERENCE STANDARD :IEC: 60228 & IEC 60502-2

POWER CABLES WITH XLPE INSULATED FOR RATED VOLTAGE OF 18/30(36)

CONDUCTOR :Compact round stranded annealed copner

INSULATION :Cross-linked polyethylene ( XLPE)

OUTER SHEATH :Black polyethylene ( Optional : Polyvinyl chloride (S 12)

CLASSIFICATION :Maximum Conductor T'emperature 90 C (Normal operation) Maximum Conductor T'emperature 250 C (Short - circuit at 5 s maximum duration)

REFERENCE STANDARD :IEC 60228 &1EC 60502-2

SAC 35 KV

CONDUCTOR :Compact stranded hard drawn Aluminum wire Conductor sizes 50 mm2 up to 240 mm2

INSULATION :Cross-linked polyethylene

INNER SHEATH :Track resistant cross-linked polyethylene Colour : Black

CLASSIFICATION :Normal operation 90°C Emergency overload conditions 130°C Short circuit conditions 250 °C Voltage rating 35 kV. (Phase to Phase)

TESTING VOLTAGE :49 kV for 5 minutes

REFERENCE STANDARD :TIS.2341-2564 (T3)

SAC 22 KV

CONDUCTOR :Compact stranded hard drawn Aluminum wire Conductor sizes 35 mm2 up to 240 mm2

INSULATION :Cross-linked polyethylene

INNER SHEATH :Track resistant cross-linked polyethylene Colour : Black

CLASSIFICATION :Normal operation 90°C Emergency overload conditions 130°C Short circuit conditions 250 °C Voltage rating 25 kV. (Phase to Phase)

TESTING VOLTAGE :38 kV for 5 minutes

REFERENCE STANDARD :ICEA S-66-524 / PEA / TIS.2341-2564 (T2)

SAC 25 KV

CONDUCTOR :Compact stranded hard drawn Aluminum wire Conductor sizes 35 mm2 up to 240 mm2

INSULATION :Cross-linked polyethylene

INNER SHEATH :Track resistant cross-linked polyethylene Colour : Black

CLASSIFICATION :Normal operation 90°C Emergency overload conditions 130°C Short circuit conditions 250 °C Voltage rating 25 kV. (Phase to Phase)

TESTING VOLTAGE :38 kV for 5 minutes

REFERENCE STANDARD :TIS.2341-2564 (T1)

PIC 35 KV

CONDUCTOR :Compact stranded hard drawn Aluminum wire Conductor sizes 35 mm2 up to 240 mm2

INSULATION :Track resistant cross-linked polyethylene Colour : Black

CLASSIFICATION :Normal operation 90 'C Emergency overload conditions 130 °C Short circuit conditions 250°C Voltage rating 35 Kv.( Phase to Phase )

TESTING VOLTAGE :17KV for 5 minutes

REFERENCE STANDARD :ICEA S-66-524 /MEA/PEA

PIC 25 KV

CONDUCTOR :Compact stranded hard drawn Aluminum wire Conductor sizes 35 mm up to 240 mm

INSULATION :Track resistant cross-linked polyethylene Colour : Black

CLASSIFICATION :Normal operation 90 °C Emergency overload conditions 130 'C Short circuit conditions 250°C Voltage rating 25 Kv.( Phase to Phase

TESTING VOLTAGE :11KV for 5 minutes

REFERENCE STANDARD :ICEA S-66-524 /MEA/PEA

POWER CABLES WITH XLPE INSULATED FOR RATED VOLTAGE OF 18/30(36)

CONDUCTOR :Compact round stranded annealed copper

INSULATION :Cross-linked polyethylene ( XLPE)

OUTER SHEATH :Black polyethylene ( Optional : Polyvinyl chloride (ST2)

CLASSIFICATION :Maximum Conductor Temperature 90 ' (Normal operation) Maximum Conductor Temperature 250 •C (Short - circuit at 5 s maximum duration)

TESTING VOLTAGE :42 Kv. For 5 minutes

REFERENCE STANDARD :IEC 60228 & IEC 60502-2

POWER CABLES WITH XLPE INSULATED FOR RATED VOLTAGE OF 12/20(24)

CONDUCTOR :Compact round stranded annealed copper

INSULATION :Cross-linked polvethylene ( XLPE

INNER SHEATH :Annealed copper wire with copper contact tape

OUTER SHEATH :Black polyethylene ( Optional : Polyvinyl chloride (S12) )

CLASSIFICATION :Maximum Conductor Temperature 90 °C (Normal operation) Maximum Conductor Temperature 250 'C (Short - circuit at 5 s maximum duration)

TESTING VOLTAGE :42 Kv. For 5 minutes

REFERENCE STANDARD :IEC 60228 & 1EC 60502-2

SAC 33 KV

CONDUCTOR :Compact stranded hard drawn Aluminum wire Conductor sizes 50 mm2 up to 240 mm2

INSULATION :Cross-linked polyethylene

INNER SHEATH :Track resistant cross-linked polyethylene Colour : Black

CLASSIFICATION :Normal operation 90°C Emergency overload conditions 130°C Short circuit conditions 250 °C Voltage rating 35 kV. (Phase to Phase)

TESTING VOLTAGE :49 kV for 5 minutes

REFERENCE STANDARD :ICEA S-66-524 / PEA / TIS.2341-2564 (T4)