60227 IEC 01 , THW, MEA TYPE A

CONDUCTOR :Solid and Standard annealed copper Size 1.5 mm2 up to 400 mm2 Polyvinyl chloride

INSULATION :Black,Light Blue, Brown, Gray, Green/Yellow , any colour

CLASSIFICATION :Maximum conductor temperature 70'C Circuit voltage not exceeding 750 volt

TESTING VOLTAGE :2,500 VAC

REFERENCE STANDARD :TIS. 11 PART 3-2553

60227 IEC 02 , THW-f

CONDUCTOR :Flexible stranded annealed copper Size 1.5 mm2 up to 240 mm2

INSULATION :Polyvinyl chloride Black, Light Blue, Brown, Gray, Green/Yellow , any colour

CLASSIFICATION :Maximum conductor temperature 70C Circuit voltage not exceeding 750 volt

TESTING VOLTAGE :2,500 VAC

REFERENCE STANDARD :TIS. 11 PART 3-2553

VAF

CONDUCTOR :Solid and Standard annealed copper Size 1.0 mm2 up to 16 mm2

INSULATION :Polyvinyl chloride (PVC) Light blue , Brown

INNER SHEATH :Polyvinylchloride (PVC) White

CLASSIFICATION :Maximum conductor temperature 70oC Circuit voltage not exceeding 500 volt

TESTING VOLTAGE :2,000 VAC

REFERENCE STANDARD :TIS.11 PART 101-2559

VAF-G (MEA Type B-G)

CONDUCTOR :Solid and Standard annealed copper Size 1.0 mm2 up to 16 mm2

INSULATION :Polyvinyl chloride (PVC) Light blue , Brown , Green/Yellow

INNER SHEATH :Polyvinyl chloride (PVC) White

CLASSIFICATION :Maximum conductor temperature 70oC Circuit voltage not exceeding 500 volt

TESTING VOLTAGE :2,000 VAC

REFERENCE STANDARD :TIS.11 PART 101-2559

NYY 1 CORE , MEA TYPE C

CONDUCTOR :Solid and Standard annealed copper Size 1.0 mm2 up to 500 mm2

INSULATION :Polyvinyl chloride (Black colour)

INNER SHEATH :Polyvinyl chloride (Black colour)

CLASSIFICATION :Maximum conductor temperature 70oC Circuit voltage not exceeding 750 volt

TESTING VOLTAGE :2,500 VAC

REFERENCE STANDARD :TIS.11 PART 101-2559

NYY 2 CORE , MEA TYPE C

CONDUCTOR :Solid and Standard annealed copper Size 1.0 mm2 up to 300 mm2

INSULATION :Polyvinyl chloride (PVC) LightBlue,Brown

INNER SHEATH :Polyvinyl chloride (Black colour)

OUTER SHEATH :Polyvinyl chloride (Black colour)

CLASSIFICATION : Maximum conductor temperature 70oC Circuit voltage not exceeding 750 volt

TESTING VOLTAGE :2,500 VAC

REFERENCE STANDARD :TIS.11PART101-2559

NYY 3 CORE , MEA TYPE C

CONDUCTOR :Solid and Standard annealed copper Size 1.0 mm2 up to 300 mm2

INSULATION :Polyvinyl chloride (PVC) Brown,Black,Grey

INNER SHEATH :Polyvinyl chloride (Black colour)

OUTER SHEATH :Polyvinyl chloride (Black colour)

CLASSIFICATION :Maximum conductor temperature 70oC Circuit voltage not exceeding 750 volt

TESTING VOLTAGE :2,500 VAC

REFERENCE STANDARD :TIS.11PART101-2559

NYY 4 CORE , MEA TYPE C

CONDUCTOR :Solid and Standard annealed copper Size 1.0 mm2 up to 300 mm2

INSULATION :Polyvinyl chloride (PVC) Light Blue , Brown , Black , Grey

INNER SHEATH :Polyvinyl chloride (Black colour)

OUTER SHEATH :Polyvinyl chloride (Black colour)

CLASSIFICATION :Maximum conductor temperature 70oC Circuit voltage not exceeding 750 volt

TESTING VOLTAGE :2,500 V. AC.

REFERENCE STANDARD :TIS.11 PART 101-2559

NYY-G 2 CORE , MEA TYPE C

CONDUCTOR :Solid and Standard annealed copper Size 1.0 mm2 up to 300 mm2

INSULATION :Polyvinyl chloride (PVC) Phase - Light blue , Brown Ground- Green/Yellow

INNER SHEATH :Polyvinyl chloride (Black colour)

OUTER SHEATH :Polyvinyl chloride (Black colour)

CLASSIFICATION :Maximum conductor temperature 70oC Circuit voltage not exceeding 750 volt

TESTING VOLTAGE :2,500 VAC

REFERENCE STANDARD :TIS.11 PART 101-2559

NYY-G 3 CORE , MEA TYPE C

CONDUCTOR :Solid and Standard annealed copper Size 1.0 mm2 up to 300 mm2

INSULATION :Polyvinyl chloride (PVC) Phase - Brown , Black , Grey Ground- Green/Yellow

INNER SHEATH :Polyvinyl chloride (Black colour)

OUTER SHEATH :Polyvinyl chloride (Black colour)

CLASSIFICATION :Maximum conductor temperature 70oC Circuit voltage not exceeding 750 volt

TESTING VOLTAGE :2,500 VAC

REFERENCE STANDARD :TIS.11 PART 101-2559

NYY-G 4 CORE , MEA TYPE C

CONDUCTOR :Solid and Standard annealed copper Size 1.0 mm2 up to 300 mm2

INSULATION :Polyvinyl chloride (PVC) Phase - Light blue , Brown , Black , Grey Ground- Green/Yellow

INNER SHEATH :Polyvinyl chloride (Black colour)

OUTER SHEATH :Polyvinyl chloride (Black colour)

CLASSIFICATION :Maximum conductor temperature 70oC Circuit voltage not exceeding 750 volt

TESTING VOLTAGE :2,500 VAC

REFERENCE STANDARD :TIS.11 PART 101-2559

VCT 2 CORES

CONDUCTOR :Flexible stranded annealed coper wire Size 1.0 mm2 up to Size 35 mm2

INSULATION :Polyvinyl chloride (PVC) Light Blue , Brown

INNER SHEATH :Polyvinyl chloride (PVC) Black colour

CLASSIFICATION :Maximum conductor temperature 70oC Circuit voltage not exceeding 750 volt

TESTING VOLTAGE :2,500 VAC

REFERENCE STANDARD :TIS. 11 PART 101-2559

VCT 4 CORES

CONDUCTOR :Flexible stranded annealed coper wire Size 1.0 mm2 up to Size 35 mm2

INSULATION :Polyvinyl chloride (PVC) Light Blue , Brown , Black , Grey

INNER SHEATH :Polyvinyl chloride (PVC) Black colour

CLASSIFICATION :Maximum conductor temperature 70oC Circuit voltage not exceeding 750 volt

TESTING VOLTAGE :2,500 VAC

REFERENCE STANDARD :TIS. 11 PART 101-2559

VCT-G 2 CORES

CONDUCTOR :Flexible stranded annealed coper wire Size 1.0 mm2 up to Size 35 mm2

INSULATION :Polyvinyl chloride (PVC) Phase - Light Blue , Brown Ground - Green/Yellow

INNER SHEATH :Polyvinyl chloride (PVC) Black colour

CLASSIFICATION :Maximum conductor temperature 70oC Circuit voltage not exceeding 750 volt

TESTING VOLTAGE :2,500 VAC

REFERENCE STANDARD :TIS. 11 PART 101-2559

VCT-G 3 CORES

CONDUCTOR :Flexible stranded annealed coper wire Size 1.0 mm2 up to Size 35 mm2

INSULATION :Polyvinyl chloride (PVC) Phase - Brown , Black , Gray Ground - Green/Yellow

INNER SHEATH :Polyvinyl chloride (PVC) Black colour

CLASSIFICATION :Maximum conductor temperature 70oC Circuit voltage not exceeding 750 volt

TESTING VOLTAGE :2,500 VAC

REFERENCE STANDARD :TIS. 11 PART 101-2559

VCT-G 4 CORES

CONDUCTOR :Flexible stranded annealed coper wire Size 1.0 mm2 up to Size 35 mm2

INSULATION :Polyvinyl chloride (PVC) Phase - Light blue , Brown , Black , Gray Ground - Green/Yellow

INNER SHEATH :Polyvinyl chloride (PVC) Black colour

CLASSIFICATION :Maximum conductor temperature 70oC Circuit voltage not exceeding 750 volt

TESTING VOLTAGE :2,500 VAC

REFERENCE STANDARD :TIS. 11 PART 101-2559

60227 IEC 01, THW, MEA TYPE A

CONDUCTOR :Solid and Standard annealed copper Size 1.5 mm2 up to 400 mm2

INSULATION :Polyvinyl chloride Black, Light Blue, Brown, Gray, Green/Yellow , any colour

CLASSIFICATION :Maximum conductor temperature 70°C Circuit voltage not exceeding 750 volt

TESTING VOLTAGE :2,500 VAC

REFERENCE STANDARD :TIS.11 PART 3-2553

60227 IEC 02 . THW-f

CONDUCTOR :Flexible stranded annealed copper Size 1.5 mm2 up to 240 mm2

INSULATION :Polyvinyl chloride Black, Light Blue, Brown, Gray, Green/Yellow , any colour

CLASSIFICATION :Maximum conductor temperature 70C Circuit voltage not exceeding 750 volt

TESTING VOLTAGE :2,500 VAC

REFERENCE STANDARD :TIS.11 PART 3-2553

60227 IEC 06 , VSF

CONDUCTOR :Flexible stranded annealed coper wire Size 0.5 mm2 up to 1.0 mm2

INSULATION :Polyvinyl chloride Black, Light Blue, Brown, Gray, Green/Yellow , any colour

CLASSIFICATION :Maximum conductor temperature 70°C Circuit voltage not exceeding 500 volt

TESTING VOLTAGE :2,000 VAC

REFERENCE STANDARD :TIS.11 PART 3-2553

60227 IEC 10

CONDUCTOR :Solid and Standard annealed copper Size 1.5 mm2 up to 35 mm2

INSULATION :Polyvinyl chloride (PVC) Brown. Black, Grey

INNER SHEATH :Polyvinyl chloride (Black colour)

OUTER SHEATH :Polyvinyl chloride (Black colour)

CLASSIFICATION :Maximum conductor temperature 70°C Circuit voltage not exceeding 500 volt

TESTING VOLTAGE :2,000 VAC

REFERENCE STANDARD :TIS.11 PART 4-2553

60227 IEC 10

CONDUCTOR :Solid and Standard annealed copper Size 1.5 mm2 up to 35 mm2

INSULATION :Polyvinyl chloride (PVC) Brown Black , Grey

INNER SHEATH :Polyvinyl chloride (Black colour)

OUTER SHEATH :Polyvinyl chloride (Black colour)

CLASSIFICATION :Maximum conductor temperature 70°C Circuit voltage not exceeding 500 volt

TESTING VOLTAGE :2,000 VAC

REFERENCE STANDARD :TIS.11 PART 4-2553

60227 IEC 10

CONDUCTOR :Solid and Standard annealed copper Size 1.5 mm2 up to 35 mm2

INSULATION :Polyvinyl chloride (PVC) Light blue , Brown , Black , Grey

INNER SHEATH :Polyvinyl chloride (Black colour)

OUTER SHEATH :Polyvinyl chloride (Black colour)

CLASSIFICATION :Maximum conductor temperature 70 C Circuit voltage not exceeding 500 volt

TESTING VOLTAGE :2,000 VAC

REFERENCE STANDARD :TIS.11 PART4-2553

60227 IEC 10

CONDUCTOR :Solid and Standard annealed copper Size 1.5 mm2 up to 35 mm2

INSULATION :Polyvinyl chloride (PVC) Light blue , Brown , Green/Yellow

INNER SHEATH :Polyvinyl chloride (Black colour)

OUTER SHEATH :Polyvinyl chloride (Black colour)

CLASSIFICATION :Maximum conductor temperature 70°C Circuit voltage not exceeding 500 volt

TESTING VOLTAGE :2,000 VAC

REFERENCE STANDARD :TIS.11 PART 4-2553

60227 IEC 10

CONDUCTOR :Solid and Standard anncaled copper Sizc 1.5 mm2 up to 35 mm2

INSULATION :Polyvinyl chloride (PVC) Brown Black Grcy Green/Yellow

INNER SHEATH :Polyvinyl chloride (Black colour)

OUTER SHEATH :Polyvinyl chloride (Black colour)

CLASSIFICATION :Maximum conductor temperaturc 70*C Circuit voltage not execeding 500) volt

TESTING VOLTAGE :2.000 volt

REFERENCE STANDARD :TIS.11 PART 4-2553

60227 IEC 52

CONDUCTOR :Flcxible stranded anncaled copcr wirc Size 0.5 0.75 mm2

INSULATION :Polyvinyl chloride (PVC) Light Blue. Brown

INNER SHEATH :Polyvinyl chloride (PVC) Black colour

OUTER SHEATH :Polyvinyl chloride (PVC) Black colour

CLASSIFICATION :Maximum conductor temperature 70°C Circuit voltage not exceeding 300 volt

TESTING VOLTAGE :2,000 VAC

REFERENCE STANDARD :TIS.II PART 5-2553

60227 IEC 52 (VKF)

CONDUCTOR :Flcxible stranded anncaled copcr wirc Size 0.5 .0.75 mm2

INSULATION :Polyvinyl chloridc (PVC) Light Blue, Brown

INNER SHEATH :Polyvinyl chloride (PVC Black colour

CLASSIFICATION :Maximum conductor temperature 70'C Circuit voltage not exceeding 300 volt

TESTING VOLTAGE :2,000 VAC

REFERENCE STANDARD :TIS.I PART 5-2553

60227 IEC 53

CONDUCTOR :Flexible stranded annealed coper wire Size 0.75 mm' up to Size 2.5 mm2

INSULATION : Polyvinyl chloride (PVC) 2 cores Light Blue, Brown 3 cores Brown , Black , Grey 4 cores Light Blue Brown, Black , Grey

INNER SHEATH :Polyvinyl chloride (PVC) : Black colour

CLASSIFICATION :Maximum conductor temperature 70°C Circuit voltage not exceeding 500 volt

TESTING VOLTAGE :2,000 VAC

REFERENCE STANDARD :TIS.11 PART 5-2553

60227 1EC 53

CONDUCTOR :Flexible stranded anncaled copcr wirc Sizc 0.75 mm' up to Sizc 2.5 mm2

INSULATION : Polyvinyl chloride (PVC) 2 cores Light Bluc , Brown and Giroon/Yellow 3 cores Brown, Black, Groy and Girocn/Ycllow 4 cores Light Blue ,Brown , Black , Grey and Green/Yellow

INNER SHEATH :Polyvinyl chloride (PVC) : Black colour

CLASSIFICATION :Maximum conductor temperaturc 70C Circuit voltage not excooding 500 volt

TESTING VOLTAGE :2,000 VAC

REFERENCE STANDARD :TIS.11 PART 5-2553

60227 IEC 53 (VKF)

CONDUCTOR :Flcxiblc stranded anncaled copcr wirc Size 0.75 1.0 mm2

INSULATION :Polyvinyl chloride (PVC) Light Blue, Brown

INNER SHEATH :Polyvinyl chloride (PVC) Black colour

CLASSIFICATION :Maximum conductor temperature 70°C Circuit voltage not exceeding 500 volt

TESTING VOLTAGE :2,000 VAC

REFERENCE STANDARD :TIS.II PART 5-2553

NAY

CONDUCTOR :Solid hard drawn aluminum wires, Sizes. 10 mm2 up to 16 mm2

INSULATION :PVC Colour : Blue

INNER SHEATH :Maximum conductor temperature 70°C Circuit voltage not exceeding 750 volts

CLASSIFICATION :Maximum conductor temperature 70°C Circuit voltage not exceeding 750 volts

TESTING VOLTAGE :2,500 Volts

REFERENCE STANDARD :TIS 293-2541 Table

THWA

CONDUCTOR :Solid and stranded hard drawn aluminum wires, Sizes. 10 mm' up to 500 mm2

INSULATION :Heat resisting PVC Colour : Black

CLASSIFICATION :Maximum conductor temperature 70°C Circuit voltage not exceeding 750 volts

TESTING VOLTAGE :2,500 Volts

REFERENCE STANDARD :TIS 293-2541 Table 1

THWA-C

CONDUCTOR :Compact stranded hard drawn aluminum wires, Sizes. 10 mm2 up to 500 mm2

INSULATION :Heat resisting PVC Colour : Black

CLASSIFICATION :Maximum conductor temperature 70°C Circuit voltage not exceeding 750 volts

TESTING VOLTAGE :2,500 Volts

REFERENCE STANDARD :TIS 293-2541 Table 2

VCT 3 CORES

CONDUCTOR :Flexible stranded annealed coper wire Size 1.0 mm2 up to Size 35 mm2

INSULATION :Polyvinyl chloride (PVC) Brown , Black , Grey

INNER SHEATH :Polyvinyl chloride (PVC) Black colour

CLASSIFICATION :Maximum conductor temperature 70oC Circuit voltage not exceeding 750 volt

TESTING VOLTAGE :2,500 VAC

REFERENCE STANDARD :TIS. 11 PART 101-2559