FUHRER WIRE AND CABLE
PRODUCTS
Sort
by Use
Infrastructure
Power Plant,
Transmission Line
Building
Factory
Additional
Product
Infrastructure
NYY 4 CORE , MEA TYPE C
Download file
CONDUCTOR :
Solid and Standard annealed copper Size 1.0 mm² up to 300 mm²
INSULATION :
Polyvinyl chloride (PVC) Light Blue , Brown , Black , Grey
INNER SHEATH :
Polyvinyl chloride (Black colour)
OUTER SHEATH :
Polyvinyl chloride (Black colour)
CLASSIFICATION :
Maximum conductor temperature 70ºC Circuit voltage not exceeding 750 volt
TESTING VOLTAGE :
2,500 V. AC.
REFERENCE STANDARD :
TIS.11 PART 101-2559
NYY 2 CORE , MEA TYPE C
Download file
CONDUCTOR :
Solid and Standard annealed copper Size 1.0 mm2 up to 300 mm2
INSULATION :
Polyvinyl chloride (PVC) LightBlue,Brown
INNER SHEATH :
Polyvinyl chloride (Black colour)
OUTER SHEATH :
Polyvinyl chloride (Black colour)
CLASSIFICATION :
Maximum conductor temperature 70oC Circuit voltage not exceeding 750 volt
TESTING VOLTAGE :
2,500 VAC
REFERENCE STANDARD :
TIS.11PART101-2559
NYY 1 CORE , MEA TYPE C
Download file
CONDUCTOR :
Solid and Standard annealed copper Size 1.0 mm² up to 500 mm²
INSULATION :
Polyvinyl chloride (Black colour)
INNER SHEATH :
Polyvinyl chloride (Black colour)
CLASSIFICATION :
Maximum conductor temperature 70oC Circuit voltage not exceeding 750 volt
TESTING VOLTAGE :
2,500 VAC
REFERENCE STANDARD :
TIS.11 PART 101-2559
NYY 3 CORE , MEA TYPE C
Download file
CONDUCTOR :
Solid and Standard annealed copper Size 1.0 mm² up to 300 mm²
INSULATION :
Polyvinyl chloride (PVC) Brown , Black , Grey
INNER SHEATH :
Polyvinyl chloride (Black colour)
OUTER SHEATH :
Polyvinyl chloride (Black colour)
CLASSIFICATION :
Maximum conductor temperature 70ºC Circuit voltage not exceeding 750 volt
TESTING VOLTAGE :
2,500 VAC
REFERENCE STANDARD :
TIS.11 PART 101-2559
Power Plant, Transmission Line
POWER CABLES WITH XLPE INSULATED FOR RATED VOLTAGE OF 18/30(36)
Download file
CONDUCTOR :
Compact round stranded annealed copper
INSULATION :
Cross-linked polyethylene ( XLPE )
OUTER SHEATH :
Black polyethylene ( Optional : Polyvinyl chloride (ST2)
CLASSIFICATION :
Maximum Conductor Temperature 90 OC (Normal operation) Maximum Conductor Temperature 250 C (Short - circuit at 5 s maximum duration)
REFERENCE STANDARD :
IEC 60228 &1EC 60502-2
SAC 25 KV
Download file
CONDUCTOR :
Compact stranded hard drawn Aluminum wire Conductor sizes 35 mm2 up to 240 mm2
INSULATION :
Cross-linked polyethylene
INNER SHEATH :
Track resistant cross-linked polyethylene Colour : Black
CLASSIFICATION :
Normal operation 90°C Emergency overload conditions 130°C Short circuit conditions 250 °C Voltage rating 25 kV. (Phase to Phase)
TESTING VOLTAGE :
38 kV for 5 minutes
REFERENCE STANDARD :
PEA / TIS.2341-2564 (T1)
SAC 22 KV
Download file
CONDUCTOR :
Compact stranded hard drawn Aluminum wire Conductor sizes 35 mm2 up to 240 mm2
INSULATION :
Cross-linked polyethylene
INNER SHEATH :
Track resistant cross-linked polyethylene Colour : Black
CLASSIFICATION :
Normal operation 90°C Emergency overload conditions 130°C Short circuit conditions 250 °C Voltage rating 25 kV. (Phase to Phase)
TESTING VOLTAGE :
38 kV for 5 minutes
REFERENCE STANDARD :
ICEA S-66-524 / PEA / TIS.2341-2564 (T2)
SAC 35 KV
Download file
CONDUCTOR :
Compact stranded hard drawn Aluminum wire Conductor sizes 50 mm2 up to 240 mm2
INSULATION :
Cross-linked polyethylene
INNER SHEATH :
Track resistant cross-linked polyethylene Colour : Black
CLASSIFICATION :
Normal operation 90°C Emergency overload conditions 130°C Short circuit conditions 250 °C Voltage rating 35 kV. (Phase to Phase)
TESTING VOLTAGE :
49 kV for 5 minutes
REFERENCE STANDARD :
ICEA S-66-524 / PEA / TIS.2341-2564 (T3)
SAC 33 KV
Download file
CONDUCTOR :
Compact stranded hard drawn Aluminum wire Conductor sizes 50 mm2 up to 240 mm2
INSULATION :
Cross-linked polyethylene
INNER SHEATH :
Track resistant cross-linked polyethylene Colour : Black
CLASSIFICATION :
Normal operation 90°C Emergency overload conditions 130°C Short circuit conditions 250 °C Voltage rating 35 kV. (Phase to Phase)
TESTING VOLTAGE :
49 kV for 5 minutes
REFERENCE STANDARD :
ICEA S-66-524 / PEA / TIS.2341-2564 (T4)
POWER CABLES WITH XLPE INSULATED FOR RATED VOLTAGE OF 12/20(24)
Download file
CONDUCTOR :
Compact round stranded annealed copper
INSULATION :
Cross-linked polyethylene ( XLPE)
OUTER SHEATH :
Black polyethylene ( Optional : Polyvinyl chloride (ST2)
CLASSIFICATION :
Maximum Conductor Temperature 90 ° (Normal operation) Maximum Conductor Temperature 250 •C. (Short - circuit at 5 s maximum duration)
TESTING VOLTAGE :
IEC 60228 & IEC. 60502-2
REFERENCE STANDARD :
42 Kv. For 5 minutes
POWER CABLES WITH XLPE INSULATED FOR RATED VOLTAGE OF 18/30(36) IEC 60502-2
Download file
CONDUCTOR :
Compact round stranded annealed copper
INSULATION :
Cross-linked polyethylene ( XLPE )
OUTER SHEATH :
Black polyethylene ( Optional : Polyvinyl chloride (ST2) )
CLASSIFICATION :
Maximum Conductor Temperature 90 °C (Normal operation) Maximum Conductor Temperature 250 'C (Short - circuit at 5 s maximum duration)
TESTING VOLTAGE :
IEC 60228 & IEC 60502-2
REFERENCE STANDARD :
42 Kv. For 5 minutes
PIC 25 KV
Download file
CONDUCTOR :
Compact stranded hard drawn Aluminum wire Conductor sizes 35 mm2 up to 240 mm2
INSULATION :
Track resistant cross-linked polyethylene Colour: Black
CLASSIFICATION :
Normal operation 90 •C Emergency overload conditions 130 •C Short circuit conditions 250°C Voltage rating 25 Kv.( Phase to Phase )
TESTING VOLTAGE :
11KV for 5 minutes
REFERENCE STANDARD :
ICEA S-66-524 /MEA/PEA
PIC 35 KV
Download file
CONDUCTOR :
Compact stranded hard drawn Aluminum wire Conductor sizes 35 mm2 up to 240 mm2
INSULATION :
Track resistant cross-linked polyethylene Colour : Black
CLASSIFICATION :
Normal operation 90 °C Emergency overload conditions 130 'C Short circuit conditions 250°C / Voltage rating 35 Kv.( Phase to Phase)
TESTING VOLTAGE :
17KV for 5 minutes
REFERENCE STANDARD :
ICEA S-66-524 /MEA/PEA
AAC
Download file
CONDUCTOR :
Concentric stranded hard drawn aluminium wires, Sizes. 16 mm2 up to 500 mm2
REFERENCE STANDARD :
TIS 85-2548
ACSR
Download file
CONDUCTOR :
Hard drawn aluminium wire Sizes. 16 mm2 up to 550 mm2
REFERENCE STANDARD :
TIS 85-2548
Building
60227 IEC 01 , THW , MEA TYPE A
Download file
CONDUCTOR :
Solid and Standard annealed copper Size 1.5 mm2 up to 400 mm2
INSULATION :
Polyvinyl chloride Black, Light Blue, Brown, Gray, Green/Yellow , any colour
CLASSIFICATION :
Maximum conductor temperature 700C Circuit voltage not exceeding 750 volt
TESTING VOLTAGE :
2,500 VAC
REFERENCE STANDARD :
TIS. 11 PART 3-2553
60227 IEC01, THW,MEA TYPE A
Download file
CONDUCTOR :
Solif and Standard annealed Copper Size 5.5 Mm2 UPTO 400 Mm2
INSULATION :
Polyvinyle chloride , Black, Light Blue, Gray , Green /Yellow , any Color
CLASSIFICATION :
Maximum Conductor Temperature 70C Circut Voltage Not exceeding 750 Volt
TESTING VOLTAGE :
2,500 VAC
REFERENCE STANDARD :
TIS.11 PART 3-2553
60227 IEC02, THW-F
Download file
CONDUCTOR :
Flexible Standard annealed Copper Size 1.5 MM2 UPTO 240MM2
INSULATION :
Polyvinyle chloride , Black , Light Blue ,Brown , Gray ,Green/Yellow, Any Colour
CLASSIFICATION :
Maximum Conductor Temperature 70C Circuit Voltage Not Exceeding 750 Volt
TESTING VOLTAGE :
2,500 VAC
REFERENCE STANDARD :
TIS.11 PART 3-2553
60227 IEC 05 IV
Download file
CONDUCTOR :
Flexible Standard annealed Copper WIRE Size 0.5 MM2 Up To 1.0 MM2
INSULATION :
Polyvinyle chloride , Black , Light Blue ,Brown , Gray ,Green/Yellow, Any Colour
CLASSIFICATION :
Maximum Conductor Temperature 70C Circuit Voltage Not Exceeding 500 Volt
TESTING VOLTAGE :
2,000 VAC
REFERENCE STANDARD :
TIS.11 PART 3-2553
60227 IEC 06 VSF
Download file
CONDUCTOR :
Flexible Standard annealed Copper WIRE Size 0.5 MM2 Up To 1.0 MM2
INSULATION :
Polyvinyle chloride , Black , Light Blue ,Brown , Gray ,Green/Yellow, Any Colour
CLASSIFICATION :
Maximum Conductor Temperature 70C Circuit Voltage Not Exceeding 500 Volt
TESTING VOLTAGE :
2,000 VAC
REFERENCE STANDARD :
TIS.11 PART 3-2553
60227 IEC10 (3)
Download file
CONDUCTOR :
Solid and Standard annealed Copper Size 1.5 MM2 Up To 35 MM2
INSULATION :
Polyvinyle chloride(PVC) , Brow , Black , Grey
INNER SHEATH :
Polyvinyle chloride(Black Colour)
OUTER SHEATH :
Polyvinyle chloride(Black Colour)
CLASSIFICATION :
Maximum Conductor Temperature 70C Circuit Voltage Not Exceeding 500 Volt
TESTING VOLTAGE :
2,000 VAC
REFERENCE STANDARD :
TIS.11 PART 4-2553
60227 IEC10 (4)
Download file
CONDUCTOR :
Solid and Standard annealed Copper Size 1.5 MM2 Up To 35 MM2
INSULATION :
Polyvinyle chloride (PVC), Brow , Black , Grey
INNER SHEATH :
Polyvinyle chloride (Black Colour)
OUTER SHEATH :
Polyvinyle chloride (Black Colour)
CLASSIFICATION :
Maximum Conductor Temperature 70C Circuit Voltage Not Exceeding 500 Volt
TESTING VOLTAGE :
2,000 VAC
REFERENCE STANDARD :
TIS.11 PART 4-2553
60227 IEC10 (5)
Download file
CONDUCTOR :
Solid and Standard annealed Copper Size 1.5 MM2 Up To 35 MM2
INSULATION :
Polyvinyle chloride(PVC) , Brow , Black , Grey
INNER SHEATH :
Polyvinyle chloride(Black Colour)
OUTER SHEATH :
Polyvinyle chloride(Black Colour)
CLASSIFICATION :
Maximum Conductor Temperature 70C Circuit Voltage Not Exceeding 500 Volt
TESTING VOLTAGE :
2,000 VAC
REFERENCE STANDARD :
TIS.11 PART 4-2553
60227 IEC10 (6)
Download file
CONDUCTOR :
Solid and Standard annealed Copper Size 1.5 MM2 Up To 35 MM2
INSULATION :
Polyvinyl chloride (PVC) , Light blue,Brown,Grey,Green/Yellow
INNER SHEATH :
Polyvinyl chloride (Black Colour)
OUTER SHEATH :
Polyvinyl chloride (Black Colour)
CLASSIFICATION :
Maximum Conductor Temperature 70C Circuit Voltage Not Exceeding 500 Volt
TESTING VOLTAGE :
2,000 VAC
REFERENCE STANDARD :
TIS.11 PART 4-2553
60227 IEC 10 (7)
Download file
CONDUCTOR :
Solid and Standard annealed Copper Size 1.5 MM2 Up To 35 MM2
INSULATION :
Polyvinyl chloride (PVC) , Light blue,Brown,Black, Grey,Green/Yellow
INNER SHEATH :
Polyvinyl chloride (Black Colour)
OUTER SHEATH :
Polyvinyl chloride (Black Colour)
CLASSIFICATION :
Maximum Conductor Temperature 70C Circuit Voltage Not Exceeding 500 Volt
TESTING VOLTAGE :
2,000 VAC
REFERENCE STANDARD :
TIS.11 PART 4-2553
60227 IEC 52
Download file
CONDUCTOR :
Flexible Standard annealed Copper Size 0.5 MM2 0.75 MM2
INSULATION :
Polyvinyl chloride (PVC) , Light blue,Brown
INNER SHEATH :
Polyvinyl chloride (PVC), Black Colour
CLASSIFICATION :
Maximum Conductor Temperature 70C Circuit Voltage Not Exceeding 300 Volt
TESTING VOLTAGE :
2,000 VAC
REFERENCE STANDARD :
TIS.11 PART 5-2553
60227 IEC 52 (2)
Download file
CONDUCTOR :
Flexible Standard annealed Copper Size 0.5 MM2 0.75 MM2
INSULATION :
Polyvinyl chloride (PVC) , Light blue,Green +yellow
INNER SHEATH :
Polyvinyl chloride (PVC), Black Colour
CLASSIFICATION :
Maximum Conductor Temperature 70C Circuit Voltage Not Exceeding 300 Volt
TESTING VOLTAGE :
2,000 VAC
REFERENCE STANDARD :
TIS.11 PART 5-2553
60227 IEC 52 (VKF)
Download file
CONDUCTOR :
Flexible Standard annealed Copper Size 0.5 MM2 0.75 MM2
INSULATION :
Polyvinyl chloride (PVC) , Light blue, Brown
INNER SHEATH :
Polyvinyl chloride (PVC), Black Colour
CLASSIFICATION :
Maximum Conductor Temperature 70C Circuit Voltage Not Exceeding 300 Volt
TESTING VOLTAGE :
2,000 VAC
REFERENCE STANDARD :
TIS.11 PART 5-2553
60227 IEC 53
Download file
CONDUCTOR :
Flexible Standard annealed Copper wire Size 0.75 MM2 2.5 MM2
INSULATION :
Polyvinyl chloride (PVC) 2 core light Brown ,3 core Brown ,Black , Grey, 4 Core light blue,brown, Black ,Grey
INNER SHEATH :
Polyvinyl chloride (PVC): Black Colour
CLASSIFICATION :
Maximum Conductor Temperature 70C Circuit Voltage Not Exceeding 500 Volt
TESTING VOLTAGE :
2,000 VAC
REFERENCE STANDARD :
TIS.11 PART 5-2553
60227 IEC 53 (2)
Download file
CONDUCTOR :
Flexible Standard annealed Copper wire Size 0.75 MM2 2.5 MM2
INSULATION :
Polyvinyl chloride (PVC) 2 core : light Blue, Brown ,Green+Yellow 3 core : Brown ,Black , Grey, Green+Yellow 4 core : Light Blue ,Brown, Black , Grey Green+Yellow
INNER SHEATH :
Polyvinyl chloride (PVC): Black Colour
CLASSIFICATION :
Maximum Conductor Temperature 70C Circuit Voltage Not Exceeding 500 Volt
TESTING VOLTAGE :
2,000 VAC
REFERENCE STANDARD :
TIS.11 PART 5-2553
60227 IEC 53 (VKF)
Download file
CONDUCTOR :
Flexible Standard anncaled Coper wire Size 0.75 MM2 1.5 MM2
INSULATION :
Polyvinyl chloride (PVC) light Blue, Brown
INNER SHEATH :
Polyvinyl chloride (PVC): Black Colour
CLASSIFICATION :
Maximum Conductor Temperature 70C Circuit Voltage Not Exceeding 500 Volt
TESTING VOLTAGE :
2,000 VAC
REFERENCE STANDARD :
TIS.11 PART 5-2553
VAF
Download file
CONDUCTOR :
Solid and Standard annealed copper Size 1.0 mm2 up to 16 mm2
INSULATION :
Polyvinyl chloride (PVC) Light blue , Brown
INNER SHEATH :
Polyvinylchloride (PVC) White
CLASSIFICATION :
Maximum conductor temperature 70oC Circuit voltage not exceeding 500 volt
TESTING VOLTAGE :
2,000 VAC
REFERENCE STANDARD :
TIS.11 PART 101-2559
VAF-G (MEA Type B-G)
Download file
CONDUCTOR :
Solid and Standard annealed copper Size 1.0 mm2 up to 16 mm2
INSULATION :
Polyvinyl chloride (PVC) Light blue , Brown , Green/Yellow
INNER SHEATH :
Polyvinyl chloride (PVC) White
CLASSIFICATION :
Maximum conductor temperature 70oC Circuit voltage not exceeding 500 volt
TESTING VOLTAGE :
2,000 VAC
REFERENCE STANDARD :
TIS.11 PART 101-2559
NYY 1 CORE , MEA TYPE C
Download file
CONDUCTOR :
Solid and Standard annealed copper Size 1.0 mm2 up to 500 mm2
INSULATION :
Polyvinyl chloride (Black colour)
INNER SHEATH :
Polyvinyl chloride (Black colour)
CLASSIFICATION :
Maximum conductor temperature 70oC Circuit voltage not exceeding 750 volt
TESTING VOLTAGE :
2,500 VAC
REFERENCE STANDARD :
TIS.11 PART 101-2559
NYY 2 CORE , MEA TYPE C
Download file
CONDUCTOR :
Solid and Standard annealed copper Size 1.0 mm2 up to 300 mm2
INSULATION :
Polyvinyl chloride (PVC) LightBlue,Brown
INNER SHEATH :
Polyvinyl chloride (Black colour)
OUTER SHEATH :
Polyvinyl chloride (Black colour)
CLASSIFICATION :
Maximum conductor temperature 70oC Circuit voltage not exceeding 750 volt
TESTING VOLTAGE :
2,500 VAC
REFERENCE STANDARD :
TIS.11PART101-2559
NYY 3 CORE , MEA TYPE C
Download file
CONDUCTOR :
Solid and Standard annealed copper Size 1.0 mm2 up to 300 mm2
INSULATION :
Polyvinyl chloride (PVC) Brown,Black,Grey
INNER SHEATH :
Polyvinyl chloride (Black colour)
OUTER SHEATH :
Polyvinyl chloride (Black colour)
CLASSIFICATION :
Maximum conductor temperature 70oC Circuit voltage not exceeding 750 volt
TESTING VOLTAGE :
2,500 VAC
REFERENCE STANDARD :
TIS.11PART101-2559
NYY 4 CORE , MEA TYPE C
Download file
CONDUCTOR :
Solid and Standard annealed copper Size 1.0 mm2 up to 300 mm2
INSULATION :
Polyvinyl chloride (PVC) Brown,Black,Grey
INNER SHEATH :
Polyvinyl chloride (Black colour)
OUTER SHEATH :
Polyvinyl chloride (Black colour)
CLASSIFICATION :
Maximum conductor temperature 70oC Circuit voltage not exceeding 750 volt
TESTING VOLTAGE :
2,500 V. AC.
REFERENCE STANDARD :
TIS.11 PART 101-2559
NYY-G 2 CORE , MEA TYPE C
Download file
CONDUCTOR :
Solid and Standard annealed copper Size 1.0 mm2 up to 300 mm2
INSULATION :
Polyvinyl chloride (PVC) Phase - Light blue , Brown Ground- Green/Yellow
INNER SHEATH :
Polyvinyl chloride (Black colour)
OUTER SHEATH :
Polyvinyl chloride (Black colour)
CLASSIFICATION :
Maximum conductor temperature 70oC Circuit voltage not exceeding 750 volt
TESTING VOLTAGE :
2,500 VAC
REFERENCE STANDARD :
TIS.11 PART 101-2559
NYY-G 3 CORE , MEA TYPE C
Download file
CONDUCTOR :
Solid and Standard annealed copper Size 1.0 mm2 up to 300 mm2
INSULATION :
Polyvinyl chloride (PVC) Phase - Brown , Black , Grey Ground- Green/Yellow
INNER SHEATH :
Polyvinyl chloride (Black colour)
OUTER SHEATH :
Polyvinyl chloride (Black colour)
CLASSIFICATION :
Maximum conductor temperature 70oC Circuit voltage not exceeding 750 volt
TESTING VOLTAGE :
2,500 VAC
REFERENCE STANDARD :
TIS.11 PART 101-2559
NYY-G 4 CORE , MEA TYPE C
Download file
CONDUCTOR :
Solid and Standard annealed copper Size 1.0 mm2 up to 300 mm2
INSULATION :
Polyvinyl chloride (PVC) Phase - Light blue , Brown , Black , Grey Ground- Green/Yellow
INNER SHEATH :
Polyvinyl chloride (Black colour)
OUTER SHEATH :
Polyvinyl chloride (Black colour)
CLASSIFICATION :
Maximum conductor temperature 70oC Circuit voltage not exceeding 750 volt
TESTING VOLTAGE :
2,500 VAC
REFERENCE STANDARD :
TIS.11 PART 101-2559
VCT 1 CORE
Download file
CONDUCTOR :
Flexible stranded annealed copper Size 1.0 mm2 up to 35 mm2
INSULATION :
Polyvinyl chloride (Black colour)
INNER SHEATH :
Polyvinyl chloride (Black colour)
CLASSIFICATION :
Maximum conductor temperature 70oC Circuit voltage not exceeding 750 volt
TESTING VOLTAGE :
2,500 VAC
REFERENCE STANDARD :
TIS.11 PART 101-2559
VCT 2 CORES
Download file
CONDUCTOR :
Flexible stranded annealed coper wire Size 1.0 mm2 up to Size 35 mm2
INSULATION :
Polyvinyl chloride (PVC) Light Blue , Brown
INNER SHEATH :
Polyvinyl chloride (PVC) Black colour
CLASSIFICATION :
Maximum conductor temperature 70oC Circuit voltage not exceeding 750 volt
TESTING VOLTAGE :
2,500 VAC
REFERENCE STANDARD :
TIS. 11 PART 101-2559
VCT 3 CORES
Download file
CONDUCTOR :
Flexible stranded annealed coper wire Size 1.0 mm2 up to Size 35 mm2
INSULATION :
Polyvinyl chloride (PVC) Brown , Black , Grey
INNER SHEATH :
Polyvinyl chloride (PVC) Black colour
CLASSIFICATION :
Maximum conductor temperature 70oC Circuit voltage not exceeding 750 volt
TESTING VOLTAGE :
2,500 VAC
REFERENCE STANDARD :
TIS. 11 PART 101-2559
VCT 4 CORES
Download file
CONDUCTOR :
Flexible stranded annealed coper wire Size 1.0 mm2 up to Size 35 mm2
INSULATION :
Polyvinyl chloride (PVC) Light Blue , Brown , Black , Grey
INNER SHEATH :
Polyvinyl chloride (PVC) Black colour
CLASSIFICATION :
Maximum conductor temperature 70oC Circuit voltage not exceeding 750 volt
TESTING VOLTAGE :
2,500 VAC
REFERENCE STANDARD :
TIS. 11 PART 101-2559
VCT-G 2 CORES
Download file
CONDUCTOR :
Flexible stranded annealed coper wire Size 1.0 mm2 up to Size 35 mm2
INSULATION :
Polyvinyl chloride (PVC) Phase - Light Blue , Brown Ground - Green/Yellow
INNER SHEATH :
Polyvinyl chloride (PVC) Black colour
CLASSIFICATION :
Maximum conductor temperature 70oC Circuit voltage not exceeding 750 volt
TESTING VOLTAGE :
2,500 VAC
REFERENCE STANDARD :
TIS. 11 PART 101-2559
VCT-G 3 CORES
Download file
CONDUCTOR :
Flexible stranded annealed coper wire Size 1.0 mm2 up to Size 35 mm2
INSULATION :
Polyvinyl chloride (PVC) Phase - Brown , Black , Gray Ground - Green/Yellow
INNER SHEATH :
Polyvinyl chloride (PVC) Black colour
CLASSIFICATION :
Maximum conductor temperature 70oC Circuit voltage not exceeding 750 volt
TESTING VOLTAGE :
2,500 VAC
REFERENCE STANDARD :
TIS. 11 PART 101-2559
VCT-G 4 CORES
Download file
CONDUCTOR :
Flexible stranded annealed coper wire Size 1.0 mm2 up to Size 35 mm2
INSULATION :
Polyvinyl chloride (PVC) Phase - Light blue , Brown , Black , Gray Ground - Green/Yellow
INNER SHEATH :
Polyvinyl chloride (PVC) Black colour
CLASSIFICATION :
Maximum conductor temperature 70oC Circuit voltage not exceeding 750 volt
TESTING VOLTAGE :
2,500 VAC
REFERENCE STANDARD :
TIS. 11 PART 101-2559
0.6/1 KV-CV
Download file
CONDUCTOR :
Concentric Standed and compact round stranded annealed copper, Size 1.5 mm2 up to 630 mm2
INSULATION :
Cross linked polythelene Colour : Natural (Translucent). Core identification Compound Colour Black ,White Red , Green. Or colour tape Light blue, Brown, Black , Gray
INNER SHEATH :
PVC, Colour : Black
CLASSIFICATION :
Maximum Conductor Temperature 90C Circuit Voltage Not Exceeding 1200 Volt
TESTING VOLTAGE :
3500 Volts
REFERENCE STANDARD :
TIS2143-2546, IEC60502-1
0.6/1(1.2)KV , MEA TYPE B
Download file
CONDUCTOR :
Solid and Standard annealed copper Size 1.0 mm2 up to 120 mm2
INSULATION :
Polyvinyl chloride (Black colour) PVC/A
INNER SHEATH :
Polyvinyl chloride (Black colour) PVC/ST1
CLASSIFICATION :
Maximum conductor temperature 70oC Circuit voltage not exceeding 1000 volt
TESTING VOLTAGE :
3,500 VAC
REFERENCE STANDARD :
TIS.2143-2546 , MEA
60227 IEC 01. THW . MEA TYPE A
Download file
CONDUCTOR :
Solid and Standard annealed copper Size 1.5 mm2 up to 400 mm2
INSULATION :
Polyvinyl chloride Black, Light Blue, Brown, Gray, Green/Yellow , any colour
CLASSIFICATION :
Maximum conductor temperature 70°C Circuit voltage not exceeding 750 volt
TESTING VOLTAGE :
2,500 VAC
REFERENCE STANDARD :
TIS.11 PART 3-2553
NAY
Download file
CONDUCTOR :
Solid hard drawn aluminum wires, Sizes. 10 mm2 up to 16 mm2
INSULATION :
PVC Colour : Blue
CLASSIFICATION :
Maximum conductor temperature 70°C Circuit voltage not exceeding 750 volts
TESTING VOLTAGE :
2,500 Volts
REFERENCE STANDARD :
TIS 293-2541 Table 1
THWA
Download file
CONDUCTOR :
Solid and stranded hard drawn aluminum wires, Sizes. 10 mm2 up to 500 mm2
INSULATION :
Heat resisting PVC Colour : Black
CLASSIFICATION :
Maximum conductor temperature 70°C Circuit voltage not exceeding 750 volts
TESTING VOLTAGE :
2.500 Volts
REFERENCE STANDARD :
TIS 293-2541 Table 1
THWA-C
Download file
CONDUCTOR :
Compact stranded hard drawn aluminum wires, Sizes. 10 mm2 up to 500 mm2
INSULATION :
Heat resisting PVC Colour : Black
CLASSIFICATION :
Maximum conductor temperature 70°C Circuit voltage not exceeding 750 volts
TESTING VOLTAGE :
2,500 Volts
REFERENCE STANDARD :
TIS 293-2541 Table 2
WEATHERPROOF
Download file
CONDUCTOR :
Compact stranded hard drawn aluminum Size 35,70,120,185 mm2
INSULATION :
Heat resistance polyethylene Black colour
CLASSIFICATION :
Maximum conductor temperature 75 C Circuit voltage not exceeding 600 volt
REFERENCE STANDARD :
ASTM D 1351-78, MEA
60227 IEC 10
Download file
CONDUCTOR :
Solid and Standard annealed Copper Size 1.5 MM2 Up To 35 MM2
INSULATION :
Polyvinyle chloride (PVC), Brow , Black , Grey
INNER SHEATH :
Polyvinyle chloride (Black Colour)
OUTER SHEATH :
Polyvinyle chloride (Black Colour)
CLASSIFICATION :
Maximum Conductor Temperature 70C Circuit Voltage Not Exceeding 500 Volt
TESTING VOLTAGE :
2,000 VAC
REFERENCE STANDARD :
TIS.11 PART 4-2553
Factory
POWER CABLES WITH XLPE INSULATED FOR RATED VOLTAGE OF 12/20(24)
Download file
CONDUCTOR :
Compact round stranded annealed copper
INSULATION :
Cross-linked polyethylene ( XLPE)
OUTER SHEATH :
Black polyethylene ( Optional : Polyyinyl chloride (ST2)
CLASSIFICATION :
Maximum Conductor T'emperature 90 C (Normal operation) Maximum Conductor Temperature 250 C. (Short - circuit at 5 s maximum duration)
TESTING VOLTAGE :
42 Kv. Hor 5 minutes
REFERENCE STANDARD :
IEC 60228 & 1EC 60502-2
POWER CABLES WITH XLPE INSULATED FOR RATED VOLTAGE OF 18/30(36)
Download file
CONDUCTOR :
Compact round stranded annealed copper
INSULATION :
Cross-linked polyethylene ( XLPE)
OUTER SHEATH :
Black polyethylene ( Optional : Polyvinyl chloride (S12)
CLASSIFICATION :
Maximum Conductor Temperature 90 C (Normal operation) Maximum Conductor Temperature 250 *C (Short - circuit at S s maximum duration)
TESTING VOLTAGE :
42 Kv. For 5 minutes
REFERENCE STANDARD :
IEC 60228 &1EC:60502-2
SAC 25 KV
Download file
CONDUCTOR :
Compact stranded hard drawn Aluminum wire Conductor sizes 35 mm2 up to 240 mm2
INSULATION :
Cross-linked polyethylene
INNER SHEATH :
Track resistant cross-linked polyethylene Colour : Black
CLASSIFICATION :
Normal operation 90°C Emergency overload conditions 130°C Short circuit conditions 250 °C Voltage rating 25 kV. (Phase to Phase)
TESTING VOLTAGE :
38 kV for 5 minutes
REFERENCE STANDARD :
TIS.2341-2564 (T1)
SAC 22 KV
Download file
CONDUCTOR :
Compact stranded hard drawn Aluminum wire Conductor sizes 35 mm2 up to 240 mm2
INSULATION :
Cross-linked polyethylene
INNER SHEATH :
Track resistant cross-linked polyethylene Colour : Black
CLASSIFICATION :
Normal operation 90°C Emergency overload conditions 130°C Short circuit conditions 250 °C Voltage rating 25 kV. (Phase to Phase)
TESTING VOLTAGE :
38 kV for 5 minutes
REFERENCE STANDARD :
ICEA S-66-524 / PEA / TIS.2341-2564 (T2)
SAC 35 KV
Download file
CONDUCTOR :
Compact stranded hard drawn Aluminum wire Conductor sizes 50 mm2 up to 240 mm2
INSULATION :
Cross-linked polyethylene
INNER SHEATH :
Track resistant cross-linked polyethylene Colour : Black
CLASSIFICATION :
Normal operation 90°C Emergency overload conditions 130°C Short circuit conditions 250 °C Voltage rating 35 kV. (Phase to Phase)
TESTING VOLTAGE :
49 kV for 5 minutes
REFERENCE STANDARD :
TIS.2341-2564 (T3)
SAC 33 KV
Download file
CONDUCTOR :
Compact stranded hard drawn Aluminum wire Conductor sizes 50 mm2 up to 240 mm2
INSULATION :
Cross-linked polyethylene
INNER SHEATH :
Track resistant cross-linked polyethylene Colour : Black
CLASSIFICATION :
Normal operation 90°C Emergency overload conditions 130°C Short circuit conditions 250 °C Voltage rating 35 kV. (Phase to Phase)
TESTING VOLTAGE :
49 kV for 5 minutes
REFERENCE STANDARD :
PEA / TIS.2341-2564 (T4)
POWER CABLES WITH XLPE INSULATED FOR RATED VOLTAGE OF 12/20(24)
Download file
CONDUCTOR :
Compact round stranded annealed copper
INSULATION :
Cross-linked polyethylene ( XLPE )
OUTER SHEATH :
Black polyethylene ( Optional : Polyvinyl chloride ($T2) )
CLASSIFICATION :
Maximum Conductor Temperature 90 °C (.Normal operation) Maximum Conductor Temperature 250 'C (Short - circuit at 5 s maximum duration)
TESTING VOLTAGE :
IEC 60228 & IEC 60502-2
REFERENCE STANDARD :
42 Kv. For 5 minutes
PIC 25 KV
Download file
CONDUCTOR :
Compact stranded hard drawn Aluminum wire Conductor sizes 35 mm2 up to 240 mm2
INSULATION :
Track resistant cross-linked polyethylene Colour : Black
CLASSIFICATION :
Normal operation 90 °C Emergency overload conditions 130 'C Short circuit conditions 250°C Voltage rating 25 Kv.( Phase to Phase)
TESTING VOLTAGE :
11KV for 5 minutes
REFERENCE STANDARD :
ICEA S-66-524 /MEA/PEA
PIC 35 KV
Download file
CONDUCTOR :
Compact stranded hard drawn Aluminum wire Conductor sizes 35 mm2 up to 240 mm2
INSULATION :
Track resistant cross-linked polyethylene Colour : Black
CLASSIFICATION :
Normal operation 90 °C Emergency overload conditions 130 •C Short circuit conditions 250°C Voltage rating 35 Kv.( Phase to Phase)
TESTING VOLTAGE :
17KV for 5 minutes
REFERENCE STANDARD :
ICEA S-66-524 /MEA/PEA
POWER CABLES WITH XLPE INSULATED FOR RATED VOLTAGE OF 18/30(36)
Download file
CONDUCTOR :
Compact round stranded annealed copper
INSULATION :
Cross-linked polyethylene ( XLPE )
OUTER SHEATH :
Black polyethylene ( Optional : Polyvinyl chloride (S12) )
CLASSIFICATION :
Maximum Conductor Temperature 90 °C (Normal operation) Maximum Conductor Temperature 250 •C. (Short - circuit at 5 s maximum duration)
TESTING VOLTAGE :
IEC. 60228 & IEC. 60502-2
REFERENCE STANDARD :
42 Kv. For 5 minutes
Additional Product
COVERED TIE WIRE
Download file
CONDUCTOR :
Solid , Soft Aluminum wire Size 16 mm2
INSULATION :
Polyvinyl Chloride (PVC)
ALUMINUM TIE WIRE
Download file
CONDUCTOR :
Solid , Soft Aluminum wire Size4&6AWG.
REFERENCE STANDARD :
MEA , ASTM B-609